1.基本信息 Basic Information
1.1执行标准 According to (Standard)
GB/T14536.1-2008:《家用和类似用途电自动控制器 第1部分:通用要求》
IEC 730-1:1994 Automatic electrols for household and similar use. Part 1:General requirements
GB/T14536.10-2008:《家用和类似用途电自动控制器 温度敏感控制器的特殊要求》
IEC 730-2-9-1992:Automatic electrical controls for household and similar use Particuar
requirements for temperature sensing controls
JB/T 3751-1997:《家用和类似用途双金属温度控制器》
JB/T 3751-1997:Bi-meral temperature controls for household and similar use
1.2构造Structure
1.2.1. 分类 Classification
属于温度固定的双金属碟片瞬动式温度控制器。
They are temperature-fixed bi-metal Snap-Action temperature controller
1.2.2.接地方式 Method Of Earth
通过温控器金属外盖与设备接地金属部件相连。
By means of the metal cup of thermostat connected in the earthing meral part.
1.2.3.外观及尺寸Appearance
外观应加工良好,无有损于性能及商品价值的伤、裂、变形、毛刺、污渍等缺陷。
The appearance should be processed well, without any defect effecting the performance or
value of the merchandise such as strain,crach,rust,distortion,besmirch,ete.
1.3动作方式Action Forms
■ 室温下触点接通(nc),温度上升触点断开,温度降低触点恢复接通。
Normal close:Cut out at temperature rise,cut in at temperature decreasing.
□室温下触点接通(nc),温度下降触点断开,温度上升触点恢复接通。
Normal close:Cut out at temperature decreasing,cut in at temperature rise.
□室温下触点断开(no),温度上升触点接通,温度降低触点恢复断开。
Normal open:Cut in at temperature rise,cut out at temperature decreasing.
□室温下触点断开(no), 温度下降触点接通,温度上升触点恢复断开。
Normal open:Cut in at temperature decreasing,cut out at temperature rise.
□室温下触点接通(nc),温度上升触点断开,温度降低手动复位接通。
Normal close:Cut out at temperature rise,manual reset at temperature decreasing.
1.4.型号命名方式Nomenclature of Type
TM 22 130 A 5 20 10A 1 R 4 D
Ⅰ Ⅱ Ⅲ Ⅳ Ⅴ Ⅵ Ⅶ Ⅷ Ⅸ Ⅹ Ⅺ
Ⅰ.工厂品牌(TM缩写)Factoy Brand(TM Abbreviation)
Ⅱ.工厂设计代号:(本厂为22等)Design Code:22
Ⅲ.动作温度:OFF及ON温度中的较高值Operating tempersture,the higher value
of OFF temp.and ON temp
Ⅳ.动作温度特性:Temperature Characteristics
A-常闭型:断开温度高于接通温度
A-Normal type:OFF temperature higher than ON temperature
K-常开型:断开温度低于接通温度
K-K type:ON temperature higher htan OFF temperature
M-手动复位型:温控器在常温下接通,断开后,不能自动复位,需要手动进行复位
M-Manual reset type:The thermostat switches on at room temperature and it won be able
to reset after switching off
O-一次动作性:温控器在室温下接通,温控器断开后,不能复位
O-One-shot type:The thermostat switches on at room temperature and it wont be able to
Reset switching off
Ⅴ.标称动作温度误差值:Open temperature difference
2表示Said±2℃
3表示Said±3℃
5表示Said±5℃
10表示Said±10℃
Ⅵ.动作温度与复位温度差值,2位Open temperature or Rstet temperature the difference
手动复位型无此项数字 The non-manual reset
Ⅶ.额定阻性负载电流:10A,15A,16A Current Rating:5A,10A,15A
Ⅷ.端子姿态Terminal Angle
1:水平Horizontal
2:垂直Vertical
3:垂直/45°Vertical/45°
4:水平/45°Horizontal/45°
5:45°/45°
6:水平/垂直Horizontal/Vertical
7:其它类型角度
3/
Ⅸ.端子类型Temrinal Type
N:187系列端子(4.8×0.5)187Series
M:187系列端子(4.8×0.8)187Series
R:250系列端子(6.3×0.8)250Series
F:非标端子Not Criterion
Ⅹ.固定形式Holder Type
1:活动固定器Free Holder
2:无固定器 Without the Holder
3:45°固定器45°Holder
4:90°固定器90°Holder
5:180°固定器180°Holder
Ⅺ.绝缘壳体Insul ating Material
D:电木Free Holder
E:陶瓷Without the Holder
P:PPS
2.主要性能Primary Performance
2.1.动作温度Operating Temperature
2.1.1.温度特性Characteristic
断电温度: 130±5℃
接通温度: 标准复位
2.1.2. 测试方法Test method
把温控器夹在测试区内,等待测温区的温度平衡后,开始测试。测试炉内以空气作为加热
介质,在测温区放置温度计或温度传感器。在温度进入动作温度公差范围前2K开始,以小于1K/min的温度变化速率进行加温或降温,其间必须进行搅拌,使温度分布充分均匀;测温区温
度分布均匀性在±0.4K以内。
测试装置可设置通断显示装置。温控器两接线端子间电压大于5V,通过试样电流大于10mA。